Thursday, December 10, 2020

Methylene Blue Reduction Test

 Aim: To determine the quality of milk by Methylene blue reductase test

Principle: Methylene Blue Dye Reduction Test, commonly known as MBRT test is a quick method to assess the microbiological quality of milk. This test is based on the fact that the methylene blue dye solution added to the milk get decolourized when the oxygen present in the milk get exhausted due to microbial activity. The sooner the decolourization, it is assumed that the more inferior is the bacteriological quality of milk.

Methylene blue is a redox indicator, that lose its color under the absence of oxygen and is thought to be reduced. The removal of the oxygen from milk and the formation of reducing substances during bacterial metabolism causes the color to disappear. The greater the number of bacteria in milk, the quicker will the oxygen be consumed, and in turn the sooner will the color disappear. Thus, the time of reduction is taken as a measure of the number of organisms in milk.

Milk is a good medium for the growth of microorganism.  A variety of microorganism can be found in both raw milk and pasteurized milk. Normally the milk is contaminated with microorganisms such as Staphylococcus aureus, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter spp., Bacillus spp., etc.  Contaminated milk is one of the important sources for transmission of diseases from animals to humans. The main reason for this contamination is the un-proper handling of milk. Normally milk is contaminated during the milking process by the microorganisms present in the exterior surface of the animals, pipelines such as udder and adjacent areas. Unsterilized dairy utensils such as milking machines, milk cans are also a good source of contamination by the microorganism.

Methylene Blue Dye Reduction Test is widely used at the dairy reception area, processing units and milk chilling centres where it is followed as acceptance/rejection criteria for the raw and processed milk

Material Required

1.      Milk samples (raw, boiled, pasteurized)

2.      Reagent: Methylene Blue dye (1:25000)

3.      Sterile screw capped tubes

4.      Water bath

5.      Bunsen burner

Procedure

  • 1.      1 mg of Methylene Blue dye was dissolved in 250 ml of sterile distilled water
  • 2.      Each of the milk samples were thoroughly mixed
  • 3.      Using different 10 ml pipettes, transfer 30 ml of each type of milk into appropriately labelled test tubes
  • 4.    3 ml of Methylene Blue dye was added to all the samples and mixed well. The colour change was noted.
  • 5.      Test tubes were closed with stopper
  • 6.      The contents of the tubes were mixed gently by inverting each test tube 2-3 times
  • 7.      The tubes were incubated in water bath at 37oC for 6 hours

Observation

Milk samples observed for Methylene Blue reduction every five minutes for the first 30 minutes and then every 30 minutes for the rset of the time. Reduction is demonstrated by decolorization of the dye.

Result

The tubes which contained the samples of packet milk showed colour change from blue to white within 3 minutes, showing Methylene Blue dye reduction test positive. Raw milk showed Methylene Blue dye reduction within 5 minutes indicating very poor quality of the milk. Disappearance of colour within the limited time indicates the absence of oxygen in milk. Hence it shows packet milk and raw milk are of poor quality. Pasteurized milk showed Methylene blue reduction within 130 minutes, indicating fair quality of the sample. Boiled milk showed Methylene blue reduction in 450 minutes indicating good quality.

 

Observations

Quality of milk sample by Methylene Blue Dye Reduction Test

Milk sample

Methylene Blue Dye Reduction Time

Quality

Packet milk

Within 30 minutes

Very poor

Raw milk

Within 30 minutes

Very poor

Pasteurized milk

130 minutes

Fair

Boiled milk

450 minutes

Good

 

Classification of Milk Quality

Methylene Blue Dye Reduction Time

Quality of milk

Approximate number of Bacteria

Within 30 minutes

Very poor quality

>2,00,00,000

31-120 minutes

Poor quality

>40,00,000 to 2,00,00,000

121-360 minutes

Fair quality

>5,00,000 to 40,00,000

361-450 minutes

Good quality

Below 500000

 